    OSYPKA PACE 203H®

    The OSYPKA PACE 203H® is a dual-chamber external pacemaker designed for the temporary stimulation of the heart in cases of heart rate disorders or signal transmission problems. With an easy-to-use interface and advanced configurations, it is ideal for daily use and for situations with complex pacing needs.

    OSYPKA PACE 203H®

    The OSYPKA PACE 203H® is a dual-chamber external pacemaker designed for the temporary stimulation of the heart in cases of heart rate disorders or signal transmission problems. With an easy-to-use interface and advanced configurations, it is ideal for daily use and for situations with complex pacing needs.


    The OSYPKA PACE 203H® is a dual-chamber external pacemaker suitable for the temporary stimulation of the heart in cases of heart rate disorders and conduction problems. This device is particularly useful in situations requiring rapid pacing and in environments with complex pacing needs. Its intuitive design and multiple configurations and displays make it perfect for both standard dual-chamber use and more demanding scenarios.

    Features

       

    • Pacing Modes: DDD, VDD, D00, VVI, V00, AAI, AAT, A00, DVI, DAI, IVA, DDD + AT, DAT
    •  

    • Basic Rate: 30 … 220 ppm
    •  

    • Upper Rate Limit: 80 … 230 ppm
    •  

    • Overdrive Pacing (atrial): 70 … 1000 ppm
    •  

    • Ventricular Rapid Pacing: 180 … 220 ppm
    •  

    • Pacing Amplitudes: 0.1 … 18 V
    •  

    • Pulse Duration: 0.05 …

    Benefits

       

    • Pacing Modes: DDD, VDD, D00, VVI, V00, AAI, AAT, A00, DVI, DAI, IVA, DDD + AT, DAT
    •  

    • Basic Rate: 30 … 220 ppm
    •  

    • Upper Rate Limit: 80 … 230 ppm
    •  

    • Overdrive Pacing (atrial): 70 … 1000 ppm
    •  

    • Ventricular Rapid Pacing: 180 … 220 ppm
    •  

    • Pacing Amplitudes: 0.1 … 18 V
    •  

    • Pulse Duration: 0.05 … 1.5 ms

    Technical data sheet