    DefiPace®

    DefiPace® is a three-chamber external pacemaker with a low-energy cardioversion function, designed for the safe and effective management of postoperative atrial fibrillation.

    DefiPace®

    DefiPace® is a three-chamber external pacemaker with a low-energy cardioversion function, designed for the safe and effective management of postoperative atrial fibrillation.


    DefiPace® represents an innovation in the temporary treatment of atrial fibrillation, combining the functions of bipolar atrial pacing and low-energy synchronized cardioversion in a single device.

    This three-chamber (A-A-V) system allows simultaneous stimulation of the left and right atria, improving electrical synchrony and reducing the recurrence of arrhythmic episodes during the postoperative period. Thanks to its cardioversion energy range of 0.5 J to 10 J, it provides safe treatment that minimises the risk of myocardial damage and reduces the need for sedation, compared with conventional external defibrillators.

    The use of specialised temporary electrodes ensures stable fixation in the left atrium, allowing precise and effective pacing for up to 7 days after cardiac surgery. Additionally, DefiPace® incorporates P-wave detection and optimal pacing thresholds, offering accurate monitoring and an immediate response to atrial electrical disturbances.

    Features

    Technical featuresDetails
    Device typeThree-chamber external pacemaker (A-A-V) with built-in low-energy cardioversion function.
    PacingBipolar atrial (Bi-A): Allows simultaneous stimulation of the left atrium and right atrium.
    Pacing chambersThree chambers: Left Atrium (LA), Right Atrium (RA) and Ventricle (V).
    Cardioversion energyLow energy: Range from 0.5 J to 10 J.
    Cardioversion modeR-wave synchronous cardioversion for safe treatment of atrial fibrillation.
    Electrode useRequires two temporary bipolar atrial electrodes and one temporary ventricular electrode.
    Duration of useDesigned for temporary postoperative use, typically up to 7 days after cardiac surgery.
    Pacing thresholdsPreliminary studies report atrial pacing thresholds (LA or RA) between 1.9 ± 1.3 V/ms and 5.0 ± 3.3 V/ms.
    SensingPreliminary studies report P-wave sensing between 0.9 ± 0.6 mV and 1.5 ± 0.7 mV.

    Benefits

    • Electrode innovation: Allows secure placement in the left atrium, essential for bipolar atrial pacing.
    • Superior safety: Low cardioversion energy (<10 J) reduces the risk of myocardial damage.
    • Reduced need for sedation: Compared with conventional defibrillators (200–360 J).
    • Functional integration: Combines pacing and cardioversion in a single external unit.
    • Enhanced postoperative efficacy: Optimises atrial electrical recovery and prevents recurrence of fibrillation.

    Technical data sheet