Skip to main content
Featured products
The OSYPKA PACE 300® is a three-chamber external pacemaker designed for temporary biventricular…
CoraSim® is a heart simulator designed for training and education in cardiac electrophysiology…
OSYPKA PACE 101H® is a single-chamber external pacemaker ideal for temporary cardiac pacing in…
Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI…
The ICONCore® is a portable, non-invasive cardiometer that enables continuous measurement of…

    VACS® II and VACS® III

    Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI procedures, stenosis treatment, and stent placement.

    VACS® II and VACS® III

    Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI procedures, stenosis treatment, and stent placement.


    The VACS® II and VACS® III dilatation catheters are designed to offer optimal performance in percutaneous transluminal valvuloplasty. They are used in TAVI procedures, stenosis treatments, and aortic valve pre-dilatation. Equipped with non-compliant balloons, these catheters can be easily positioned over a guidewire. The VACS® II models offer a low profile for use with small introducers, while the VACS® III models incorporate a reinforced balloon segment to withstand high pressure.

    Features

    • Coaxial design for enhanced stability.
    • Non-compliant balloon for precision in dilatation.
    • Guidewire compatibility for easy positioning.
    • VACS® II with a low profile for small introducers.
    • VACS® III with a reinforced balloon for higher pressure resistance.

    Benefits

    • Facilitates valvular preparation in TAVI procedures.
    • Enables the use of smaller introducers, reducing vascular trauma.
    • High inflation pressure for demanding clinical cases.
    • Easy navigation and positioning over a guidewire.
    • Options tailored to different therapeutic needs with VACS® II and III.

    Other data

    VACS® II

    Thin and soft balloon material to minimise the vascular access profile in paediatric procedures, as well as in palliative or valvuloplasty bridge cases.

    VACS® III

    Outstanding pressure and tear-resistant balloon material for rigid or highly calcified lesions.
    Improved shaft design for shorter inflation and deflation times.

    Y-Connector

    Improved Y-Connector and other features that provide convenient handling and reliability for the special requirements of TAVI procedures.

    Technical data sheet

    vacs ii vacs iii 2 biogen
    vacs ii vacs iii 1 biogen

    Indications

    • Aortic valve pre-dilatation in TAVI procedures
    • Aortic isthmus stenosis
    • Right and left ventricular outflow tract stenosis
    • Pulmonary valve stenosis
    • Aortic valve stenosis
    • Peripheral pulmonary artery stenosis

    Special features

    • Atraumatic tip
    • Short inflation and deflation time
    • Radiopaque gold markers
    • Wide range of sizes for maximum flexibility

    Technical specifications

    • Balloon diameter: 4–30 mm / 5–30 mm
    • Balloon length: 20–60 mm / 20–60 mm
    • Rated burst pressure: 6–15 atm / 15–4 atm
    Indications
    vacs ii vacs iii 4 biogen
    • Aortic valve pre-dilatation in TAVI procedures
    • Aortic isthmus stenosis
    • Right and left ventricular outflow tract stenosis
    • Pulmonary valve stenosis
    • Aortic valve stenosis
    • Peripheral pulmonary artery stenosis
    Special features
    vacs ii vacs iii 5 biogen
    • A-traumatic tip
    • Short inflation and deflation time
    • Radiopaque gold markers
    • Wide range of sizes for maximum flexibility
    Technical specifications
    vacs ii vacs iii 3 biogen
    • Balloon Diameter: 4-30 mm / 5-30 mm
    • Balloon Length: 20-60 mm / 20-60 mm
    • Rated Burst Pressure: 6-1.5 atm / 15-4 atm