Skip to main content
Featured products
Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI…
Temporary myocardial pacing cables intended for use after cardiac surgery. Available in multiple…
The ICONCore® is a portable, non-invasive cardiometer that enables continuous measurement of…
CoraSim® is a heart simulator designed for training and education in cardiac electrophysiology…
OSYPKA PACE 101H® is a single-chamber external pacemaker ideal for temporary cardiac pacing in…

    VACS® II and VACS® III

    Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI procedures, stenosis treatment, and stent placement.

    VACS® II and VACS® III

    Balloon dilatation catheter for percutaneous transluminal valvuloplasty, ideal for TAVI procedures, stenosis treatment, and stent placement.


    The VACS® II and VACS® III dilatation catheters are designed to offer optimal performance in percutaneous transluminal valvuloplasty. They are used in TAVI procedures, stenosis treatments, and aortic valve pre-dilatation. Equipped with semi-compliant balloons, these catheters can be easily positioned over a guidewire. The VACS® II models offer a low profile for use with small introducers, while the VACS® III models incorporate a reinforced balloon segment to withstand high pressure.

    Features

    • Coaxial design for enhanced stability.
    • Semi-compliant balloon for precision in dilatation.
    • Guidewire compatibility for easy positioning.
    • VACS® II with a low profile for small introducers.
    • VACS® III with a reinforced balloon for higher pressure resistance.

    Benefits

    • Facilitates valvular preparation in TAVI procedures.
    • Enables the use of smaller introducers, reducing vascular trauma.
    • High inflation pressure for demanding clinical cases.
    • Easy navigation and positioning over a guidewire.
    • Options tailored to different therapeutic needs with VACS® II and III.

    Other data

    VACS® II

    Thin and soft balloon material to minimise the vascular access profile in paediatric procedures, as well as in palliative or valvuloplasty bridge cases.

    VACS® III

    Outstanding pressure and tear-resistant balloon material for rigid or highly calcified lesions.
    Improved shaft design for shorter inflation and deflation times.

    Y-Connector

    Improved Y-Connector and other features that provide convenient handling and reliability for the special requirements of TAVI procedures.

    Technical data sheet

    vacs ii vacs iii 2 biogen
    vacs ii vacs iii 1 biogen

    Indications

    • Aortic valve pre-dilatation in TAVI procedures
    • Aortic isthmus stenosis
    • Right and left ventricular outflow tract stenosis
    • Pulmonary valve stenosis
    • Aortic valve stenosis
    • Peripheral pulmonary artery stenosis

    Special features

    • Atraumatic tip
    • Short inflation and deflation time
    • Radiopaque gold markers
    • Wide range of sizes for maximum flexibility

    Technical specifications

    • Balloon diameter: 4–30 mm / 5–30 mm
    • Balloon length: 20–60 mm / 20–60 mm
    • Rated burst pressure: 6–15 atm / 15–4 atm
    Indications
    vacs ii vacs iii 4 biogen
    • Aortic valve pre-dilatation in TAVI procedures
    • Aortic isthmus stenosis
    • Right and left ventricular outflow tract stenosis
    • Pulmonary valve stenosis
    • Aortic valve stenosis
    • Peripheral pulmonary artery stenosis
    Special features
    vacs ii vacs iii 5 biogen
    • A-traumatic tip
    • Short inflation and deflation time
    • Radiopaque gold markers
    • Wide range of sizes for maximum flexibility
    Technical specifications
    vacs ii vacs iii 3 biogen
    • Balloon Diameter: 4-30 mm / 5-30 mm
    • Balloon Length: 20-60 mm / 20-60 mm
    • Rated Burst Pressure: 6-1.5 atm / 15-4 atm