<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Peripheral angioplasty - Biogen Diagnóstica</title>
	<atom:link href="https://biogendiagnostica.com/en/product-category/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/feed/" rel="self" type="application/rss+xml" />
	<link>https://biogendiagnostica.com/en/product-category/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/</link>
	<description>Biogen Diagnóstica es una compañía con más de 20 años de experiencia en el campo de la Salud y la tecnología médica. Productos para el diagnóstico, la prevención, el tratamiento y el cuidado de los pacientes.</description>
	<lastBuildDate>Mon, 09 Mar 2026 13:16:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://biogendiagnostica.com/wp-content/uploads/cropped-logo-sitio-biogen-1-1-1000-32x32.png</url>
	<title>Peripheral angioplasty - Biogen Diagnóstica</title>
	<link>https://biogendiagnostica.com/en/product-category/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Trift SC PTA balloon 0.035” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/trift-sc-pta-balloon-0-035-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 13:35:22 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/balon-pta-sc-0-035-otw-trift/</guid>

					<description><![CDATA[<p><strong>Trift</strong> is a <strong>semi compliante angioplasty balloon</strong> OTW 0.035", designed to treat <strong>peripheral lesions</strong> with high efficacy, offering <strong>high radial strength</strong> and <strong>precise expansion</strong>.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/trift-sc-pta-balloon-0-035-otw/">Trift SC PTA balloon 0.035” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Trift SC PTA balloon 0.035” OTW</strong> has been developed to offer a robust and versatile solution in peripheral angioplasty procedures where larger diameters and additional strength are required.</p>
<p>The Trift SC PTA balloon 0.035” OTW is made from a <strong>semi compliante</strong> material that ensures progressive and controlled expansion, with a <strong>nominal pressure of 8 atm</strong> and a <strong>burst pressure of up to 14 atm</strong>.</p>
<p>Compatible with 0.035&#8243; guidewires, its <strong>wide inner lumen</strong> enhances visibility and facilitates advancement in iliac, femoral, or large-calibre vessels.</p>
<p><strong>Trift</strong> provides an effective solution for <strong>resistant stenoses</strong> or vessels with mild to moderate calcification, offering high pushability and control.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/trift-sc-pta-balloon-0-035-otw/">Trift SC PTA balloon 0.035” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Skinny SC PTA balloon 0.018” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/skinny-sc-pta-balloon-0-018-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 13:27:32 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/pta-balloon-sc-0-018-otw-skinny/</guid>

					<description><![CDATA[<p><strong>Skinny</strong> is a <strong>semi compliante angioplasty balloon</strong> OTW 0.018", designed to provide controlled and effective dilatation in peripheral vessels, with excellent flexibility and a low profile.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/skinny-sc-pta-balloon-0-018-otw/">Skinny SC PTA balloon 0.018” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Skinny SC PTA balloon 0.018” OTW</strong> combines an ultra-low profile design with great navigability, allowing effective access to complex peripheral anatomies. Its flexible and durable shaft provides excellent pushability and control during dilatation.</p>
<p>The balloon is made from <strong>semi compliante</strong> materials that ensure precise expansion with a nominal pressure of 8 atm and a burst pressure of up to 14 atm. Its controlled behaviour minimises the risk of vascular perforations or dissections.</p>
<p>Compatible with 0.018&#8243; OTW systems, the <strong>Skinny SC PTA balloon 0.018” OTW</strong> is indicated for the dilatation of stenoses in peripheral arteries, including small-calibre vessels where high precision is required.</p>
<p>Available in a wide range of diameters (2.0–7.0 mm) and lengths (20–200 mm), it offers versatile solutions for various clinical needs.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/skinny-sc-pta-balloon-0-018-otw/">Skinny SC PTA balloon 0.018” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Zeeland SC PTA balloon 0.014” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/zeeland-sc-pta-balloon-0-014-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 13:22:40 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/pta-balloon-sc-0-014-otw-zeeland/</guid>

					<description><![CDATA[<p><strong>Zeeland</strong> is a <strong>semi compliante (SC) balloon</strong> of 0.014" for peripheral angioplasty, designed with an <strong>Over-The-Wire (OTW)</strong> system that offers excellent navigability and adaptability in small-calibre vessels.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/zeeland-sc-pta-balloon-0-014-otw/">Zeeland SC PTA balloon 0.014” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Zeeland SC PTA balloon 0.014” OTW</strong> has been developed to provide an optimal balance between <strong>flexibility, navigability, and effective dilatation</strong> in peripheral interventions. Its semi compliante design allows slight balloon expansion that facilitates anatomical adaptation, reducing vascular trauma.</p>
<p>Compatible with 0.014&#8243; guidewires, the <strong>Zeeland SC PTA balloon 0.014” OTW</strong> stands out for its <strong>ultra-low distal profile</strong> and its ability to reach <strong>narrow and tortuous vessels</strong>. It offers a nominal pressure of 6 atm and can reach up to 14 atm without compromising balloon integrity.</p>
<p>Available in <strong>diameters from 1.5 to 4.0 mm</strong> and lengths up to 220 mm, it is ideal for treating distal lesions in the lower limbs.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/zeeland-sc-pta-balloon-0-014-otw/">Zeeland SC PTA balloon 0.014” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Millau NC PTA balloon 0.035” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/millau-nc-pta-balloon-0-035-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 13:13:59 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/pta-balloon-nc-0-035-otw-millau/</guid>

					<description><![CDATA[<p><strong>Millau</strong> is a <strong>non-compliant PTA balloon</strong> of 0.035", designed for demanding peripheral interventions where high expansion capability and precise control are required, with an <strong>Over-The-Wire (OTW)</strong> system.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/millau-nc-pta-balloon-0-035-otw/">Millau NC PTA balloon 0.035” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Millau NC PTA balloon 0.035” OTW</strong> is indicated for peripheral angioplasty procedures in large-calibre vessels. Thanks to its <strong>non-compliant design</strong>, the Millau NC PTA balloon 0.035” OTW allows high pressures to be reached without losing its cylindrical shape, offering <strong>controlled and effective dilatation</strong> in challenging lesions.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/millau-nc-pta-balloon-0-035-otw/">Millau NC PTA balloon 0.035” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Erasmus NC PTA balloon 0.018” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/erasmus-nc-pta-balloon-0-018-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 13:04:58 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/pta-balloon-nc-0-018-otw-erasmus/</guid>

					<description><![CDATA[<p><strong>Erasmus</strong> is a <strong>non-compliant peripheral angioplasty balloon</strong> of 0.018", with <strong>Over-The-Wire (OTW)</strong> technology, designed to deliver high performance in complex and resistant vascular procedures.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/erasmus-nc-pta-balloon-0-018-otw/">Erasmus NC PTA balloon 0.018” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Erasmus NC PTA balloon 0.018” OTW</strong> is a <strong>non-compliant PTA balloon</strong> that combines high pressure with a low profile, providing effective dilatation in severely stenosed or calcified peripheral arteries. Its OTW design with a 0.018&#8243; guidewire enables precise control and excellent responsiveness during the intervention.</p>
<p>Thanks to its <strong>cylindrical balloon structure</strong> and high-strength material, the ensures <strong>uniform dilatation without overstretching</strong>. Additionally, its braided shaft allows effective pushability, while the flexible distal shaft improves navigability even in complex anatomies.</p>
<p>The Erasmus NC PTA balloon 0.018” OTW withstands a <strong>nominal pressure of 12 atm</strong> and a <strong>burst pressure of up to 20 atm</strong>, enabling safe treatment of fibrous or resistant lesions.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/erasmus-nc-pta-balloon-0-018-otw/">Erasmus NC PTA balloon 0.018” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rialto NC PTA balloon 0.014” OTW</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/rialto-nc-pta-balloon-0-014-otw/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 14 May 2025 12:49:40 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/pta-balloon-nc-0-014-otw-rialto/</guid>

					<description><![CDATA[<p><strong>Rialto</strong> is a <strong>non-compliant peripheral angioplasty balloon</strong> of 0.014", designed to provide high precision, durability, and control in complex vascular lesions, with OTW compatibility.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/rialto-nc-pta-balloon-0-014-otw/">Rialto NC PTA balloon 0.014” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Rialto NC PTA balloon 0.014” OTW</strong> is a <strong>non-compliant PTA dilation balloon</strong> of 0.014&#8243; with an <strong>Over-The-Wire (OTW)</strong> system, providing controlled expansion even in resistant or calcified vessels. Its cylindrical design and folding technology minimise the profile, facilitating navigation in narrow or tortuous arteries.</p>
<p>It is available in <strong>balloon lengths from 10 to 40 mm</strong> and <strong>diameters ranging from 2.0 mm to 5.0 mm</strong>, allowing precise treatment of multiple types of peripheral lesions. The braided proximal shaft ensures excellent pushability, while the polymer distal shaft provides flexibility and tracking.</p>
<p>It features a <strong>nominal pressure of 12 atm</strong> and a <strong>burst pressure of up to 20 atm</strong>, delivering superior performance in challenging interventions.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/rialto-nc-pta-balloon-0-014-otw/">Rialto NC PTA balloon 0.014” OTW</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Atlas peripheral stent</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-peripheral-stent/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 30 Apr 2025 15:09:26 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/atlas-peripheral-stent/</guid>

					<description><![CDATA[<p><strong>Atlas</strong> is a <strong>self-expanding peripheral stent</strong> designed for lesions in the femoral, iliac, or popliteal arteries, offering <strong>reliable radial support</strong> and low rates of <strong>restenosis</strong> in interventions for <strong>peripheral arterial disease (PAD)</strong>.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-peripheral-stent/">Atlas peripheral stent</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Atlas peripheral stent</strong> sets a new standard in the treatment of <strong>peripheral arterial disease</strong>, thanks to its robust, flexible, and highly precise design.</p>
<p>Indicated for vessel diameters between 5 mm and 8 mm and lesion lengths from 20 mm to 200 mm, it is ideal for areas at high risk of sudden closure or restenosis following balloon angioplasty (PTA).</p>
<p>Manufactured from <strong>nitinol alloy</strong> using laser cutting, this <strong>self-expanding stent</strong> offers a safe and minimally invasive alternative to traditional open surgery.</p>
<p>Its triaxial delivery system is designed for stable, controlled, and precise deployment, compatible with <strong>0.035” guidewires</strong> and available in catheter lengths of 80 and 120 cm.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-peripheral-stent/">Atlas peripheral stent</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Atlas stent graft</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-stent-graft/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Wed, 30 Apr 2025 14:57:49 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/atlas-stent-graft/</guid>

					<description><![CDATA[<p><strong>Atlas</strong> is a <strong>covered peripheral stent graft</strong> that provides secure occlusion of <strong>aneurysms</strong> or <strong>occlusive lesions</strong> in the iliac or femoral segments, minimising the risk of <strong>rupture</strong> or <strong>reocclusion</strong>.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-stent-graft/">Atlas stent graft</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Atlas stent graft</strong> offers an advanced solution for <strong>endovascular repair</strong>, combining a self-expanding nitinol structure with a robust <strong>carbon coating</strong> and a microporous <strong>ePTFE membrane</strong>.</p>
<p>The Atlas stent graft open and flexible design adapts to various vascular anatomies, optimising blood flow and minimising turbulence. <strong>Tantalum markers</strong> at both ends enhance visibility under fluoroscopy, allowing for precise placement.</p>
<p>With a wide range of diameters and lengths, and an encapsulated construction to resist <strong>neointimal hyperplasia</strong>, Atlas is ideal for treating <strong>aneurysms</strong>, <strong>stenoses</strong>, and <strong>occlusive peripheral lesions</strong>.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/atlas-stent-graft/">Atlas stent graft</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Extender paclitaxel-eluting PTA balloon</title>
		<link>https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/extender-paclitaxel-eluting-pta-balloon/</link>
		
		<dc:creator><![CDATA[admin_bio_esc]]></dc:creator>
		<pubDate>Mon, 14 Apr 2025 10:28:14 +0000</pubDate>
				<guid isPermaLink="false">http://biogendiagnostica.com/productos/uncategorized/extender-paclitaxel-eluting-pta-balloon/</guid>

					<description><![CDATA[<p>A <strong>drug-eluting balloon (DCB)</strong> with <strong>paclitaxel</strong> for angioplasty in <strong>peripheral arterial disease</strong> above the knee.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/extender-paclitaxel-eluting-pta-balloon/">Extender paclitaxel-eluting PTA balloon</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Extender paclitaxel-eluting PTA balloon</strong> is a <strong>paclitaxel-coated balloon dilatation catheter</strong>, specially designed for <strong>percutaneous transluminal angioplasty (PTA)</strong> in the treatment of <strong>peripheral arterial disease (PAD)</strong>.</p>
<p>Optimized for <strong>supra-patellar peripheral interventions</strong>, the Extender paclitaxel-eluting PTA balloon combines mechanical efficacy with precise drug delivery. Its <strong>advanced coating</strong> allows for controlled administration of <strong>paclitaxel</strong>, a potent <strong>anti-restenotic</strong> agent, during brief inflations, reducing drug loss and maximizing its therapeutic efficacy.</p>
<p>With a technology that improves drug retention at the lesion site, <strong>Extender</strong> offers a minimally invasive alternative to prevent restenosis after PTA procedures.</p>
<p>La entrada <a href="https://biogendiagnostica.com/en/products/vascular-surgery-and-intervention-peripheral-venous/vascular-interventionalism/peripheral-angioplasty/extender-paclitaxel-eluting-pta-balloon/">Extender paclitaxel-eluting PTA balloon</a> se publicó primero en <a href="https://biogendiagnostica.com/en/">Biogen Diagnóstica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
